INSTALLATION INSTRUCTIONS
TA12PS, TA12BF/WBF, TA12SL, TA12C/G
InstructionSheet
www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET
701 Millennium Blvd., • Greenville, SC 29607
With representatives of
fices in principal cities throughout North
America.
Copyright 2007, 11/05 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23796-PRE
InstructionSheet
*******************************************************************************************************************************************************************************
WARNING - IF ANY SPECIAL CONTROL DEVICES ARE USED WITH THIS FIXTURE, FOLLOW THE INSTRUCTIONS CAREFULLY
TO ASSURE FULL COMPLIANCE WITH N.E.C. REQUIREMENTS. IF THERE ARE ANY QUESTIONS, CONTACT A QUALIFIED
ELECTRICAL CONTRACTOR.
*
******************************************************************************************************************************************************************************
CAUTION:- All Glass is Fragile, use care when Handling Lamp.
1.- Install the Fixture Housing (1) in the Ceiling (2) according to the Instructions
supplied with the Fixture.
2.- Lower the Socket (3) and install the proper Lamp (10) (not furnished) as per
the wattage Label inside Housing.
3.- Place the Glass Lens (4) in the bottom of the Lampholder Cup (5).
4.- Holding the Socket Reflector (6) firmly, press one edge of the Lamp under the Spring (7)
in the Lampholder Cup until the opposite side can be inserted under the Lance (8).
5.- Rotate Spring (11) Clockwise inside Retention Bracket (12) to tighten.
6.- Orient the Trim (9) so that the Lamp is aimed in the desired direction.
Center the
Trim in the Housing and push upward untl the Flange is flush with the Ceiling.
To Relamp:
1.- Remove Trim (9) from Ceiling (2) by turning Trim (9) counter-clockwise.
Retention Bracket (12) will release from Spring (1
1).
(Retention Bracket (12) should loosen without much force).
2.- To retrieve Spring (10), reach up inside Housing (1). Attach Spring (11) to
Retention Bracket (12) before inserting Lens (5) into Ceiling (2).
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions
concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do not
install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn off power
at fuse or circuit breaker.
All servicing or relamping must be performed by qualified service personnel. Product must be ground-
ed to avoid potential electric shock or other potential hazard. Product must be mounted in locations and at heights and in a man-
ner consistent with its intended use, and in compliance with the National Electrical Code and local codes. The use of accessory
equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light
emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.